{"product_id":"shurflo-water-pump-12v-100-psi-male-ports","title":"Shurflo Water Pump 12V 100 PSI Male Ports","description":"\u003ch2\u003eShurflo 8000-946-138 12V 100 PSI Window-Cleaning Pump\u003c\/h2\u003e\n\u003cp\u003eThe Shurflo 8000-946-138 is a reliable 12V diaphragm pump designed for water-fed pole and pure-water window-cleaning systems. It delivers pressure up to 100 PSI with an open-flow rate of approximately 5.2 litres per minute, making it suitable for van-mounted and trolley-based systems.\u003c\/p\u003e\n\u003cp\u003eIts self-priming design, compact construction and efficient power consumption make it a dependable choice for professional window cleaners working with long hose runs and high-reach water-fed poles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT: THIS LISTING IS FOR THE PUMP ONLY. NO STRAINER, FITTINGS, CONTROLLER, HOSES, WIRING ACCESSORIES OR OTHER ACCESSORIES ARE INCLUDED.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eReliable 100 PSI Performance\u003c\/h3\u003e\n\u003cp\u003eThe pump provides the pressure required to move pure water through long lengths of microbore hose and up water-fed poles. Actual pressure and flow at the brush head will vary depending on the hose length, pole height, controller settings, battery condition and system configuration.\u003c\/p\u003e\n\u003cp\u003eThe diaphragm design allows the pump to self-prime and run dry without immediate damage. However, regularly running the pump without water should be avoided wherever possible.\u003c\/p\u003e\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eWhat It Means for You\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 100 PSI\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProvides strong water delivery through long hose runs and high-reach poles.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5.2 LPM Open Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplies sufficient water for a typical single-operator water-fed pole system.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSelf-Priming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDraws water from a tank without requiring manual priming under normal installation conditions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDry-Running Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHelps protect the pump if the water supply is temporarily interrupted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e12V DC Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuitable for use with leisure batteries in mobile and van-mounted systems.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFits easily into restricted van, trolley and equipment-board installations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuilt-In Pressure Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatically stops the pump when the outlet is closed or the preset pressure is reached.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShurflo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8000-946-138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-priming diaphragm pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen-Flow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 5.2 litres per minute (1.4 US GPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch male threaded ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in pressure switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-operator water-fed pole system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSuitable Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater-fed pole window cleaning:\u003c\/strong\u003e Supplies pure water from van-mounted or trolley-based tanks to water-fed brushes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommercial exterior cleaning:\u003c\/strong\u003e Suitable for cleaning windows and building façades where mains water pressure is unavailable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMobile pure-water systems:\u003c\/strong\u003e Ideal for professional systems powered by a suitable 12V leisure battery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement pump installations:\u003c\/strong\u003e Suitable for replacing a compatible 12V, 100 PSI pump with matching connections and electrical requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Professionals Choose Shurflo\u003c\/h3\u003e\n\u003cp\u003eShurflo pumps are widely used in professional window-cleaning systems because of their dependable diaphragm technology, compact design and ability to provide consistent pressure.\u003c\/p\u003e\n\u003cp\u003eThe 8000-946-138 offers a practical balance of pressure, water flow and power consumption for everyday water-fed pole work. When installed with a suitable strainer, fuse and correctly calibrated flow controller, it can provide reliable service in demanding mobile cleaning systems.\u003c\/p\u003e\n\u003ch3\u003eInstallation, Safety and Maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtect the pump from frost:\u003c\/strong\u003e Drain the pump and connected pipework during freezing weather. Water expanding inside the pump can crack the housing and cause permanent damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeep the motor and electrical connections dry:\u003c\/strong\u003e Mount the pump where it is protected from rain, leaks and water spills.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstall an inlet strainer:\u003c\/strong\u003e A suitable strainer must be fitted before the pump inlet to prevent resin, dirt and other debris from entering the pump head.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUse a suitable fuse:\u003c\/strong\u003e Install an appropriately rated inline fuse on the positive electrical connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUse a flow controller:\u003c\/strong\u003e A correctly calibrated digital controller regulates the water flow, reduces unnecessary battery use and prevents repeated pressure-switch cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck all connections:\u003c\/strong\u003e Make sure the inlet and outlet fittings are properly fitted without overtightening or damaging the pump ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDo not dismantle the motor:\u003c\/strong\u003e Internal repairs should only be completed by a suitably qualified person.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Information\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Shurflo 12V pump is supplied with a limited warranty.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe warranty does not cover damage caused by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eFreezing or ice expansion inside the pump.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater entering the motor or electrical components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResin, dirt or other debris entering the pump.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncorrect wiring, unsuitable power supplies or electrical short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproper installation, misuse or unauthorised modifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating the pump outside its intended specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsing an incorrectly calibrated controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen used as part of a water-fed pole system, the pump should be connected to a suitable flow controller that has been correctly installed and calibrated.\u003c\/p\u003e\n\u003ch3\u003eInstallation Directions\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFit an inlet strainer:\u003c\/strong\u003e Attach a compatible 1\/2-inch strainer to the inlet side before connecting the water supply. This protects the pump from resin and tank debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFit the required connections:\u003c\/strong\u003e Attach compatible 1\/2-inch female fittings to the inlet and outlet ports. Do not overtighten them.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstall an inline fuse:\u003c\/strong\u003e Fit a suitable fuse to the positive power cable to protect the pump and wiring from excessive current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnect a flow controller:\u003c\/strong\u003e Wire the pump through a compatible digital flow controller according to the controller manufacturer’s instructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCheck the water supply:\u003c\/strong\u003e Make sure the tank contains sufficient water and that all valves between the tank and pump are open.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBleed the system:\u003c\/strong\u003e Switch on the pump and allow water to run freely until any trapped air has cleared and the flow becomes steady.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibrate the controller:\u003c\/strong\u003e Adjust the flow and calibration settings to match the hose, pole and brush configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are fittings and a strainer included with this pump?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. This listing is for the pump only. Strainers, fittings, controllers, hoses, wiring accessories and all other accessories must be purchased separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fittings are required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The pump has 1\/2-inch male threaded ports. Compatible 1\/2-inch female Shurflo fittings are available in straight and elbow configurations. Check compatibility before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this pump suitable for a water-fed pole system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It is commonly used in single-operator pure-water window-cleaning systems, including van-mounted and trolley-based installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the pump be connected directly to a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The pump can operate from a suitable 12V power supply, but a correctly calibrated digital flow controller is strongly recommended for water-fed pole use. A controller regulates flow, reduces water consumption and limits unnecessary pressure-switch cycling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the pump pulsing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Pulsing usually means the pressure switch is repeatedly activating. This may be caused by an incorrectly calibrated controller, restricted water flow, a kinked hose, blocked jets or another obstruction in the outlet line.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why has the pump stopped building pressure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Common causes include an empty tank, an airlock, a blocked inlet strainer, a restricted hose, low battery voltage or debris trapped inside the pump head.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What battery should be used?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: A deep-cycle leisure battery is normally used. The required capacity depends on the working time, controller setting, pump load, battery condition and any other equipment connected to the battery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the pump be used with hot pure water?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Only use the pump within the manufacturer’s permitted fluid-temperature range. Do not connect it to an unregulated hot-water supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExpert Tip:\u003c\/strong\u003e Correct controller calibration is essential. A setting that is too high or poorly calibrated can cause pressure-switch cycling, unnecessary battery use and increased wear. Do not bypass or modify the internal pressure switch unless this is specifically authorised by the manufacturer.\u003c\/p\u003e","brand":"CLEANING SPOT","offers":[{"title":"Default Title","offer_id":54748439904597,"sku":"8000-946-138","price":124.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1021\/7907\/8485\/files\/Yourparagraphtext_095d07f4-18bf-4eb0-8bf1-03eedef1e5a6.png?v=1787662195","url":"https:\/\/securecleaningsystems.co.uk\/products\/shurflo-water-pump-12v-100-psi-male-ports","provider":"Secure Cleaning Systems","version":"1.0","type":"link"}